Circuit/System Testing
- Ignition OFF, disconnect the harness connector at the IMT solenoid.
- Ignition ON, verify that a test lamp illuminates between the ignition voltage circuit terminal 1 and ground.
- If the test lamp does not illuminate, test the circuit for a short to ground or an open/high resistance. If the circuit tests normal and the ignition circuit fuse is open, test all the components connected to the ignition circuit and replace as necessary.
- Ignition OFF, connect a test lamp between the control circuit terminal 2 and the ignition voltage circuit terminal 1.
- Ignition ON, command the IMT solenoid ON and OFF with a scan tool. The test lamp should turn ON and OFF.
- If the test lamp remains ON all the time, test for a short to ground on the control circuit. If circuit/connections test normal, replace the ECM.
- If the test lamp remains OFF all the time, test for a short to voltage or an open/high resistance on the control circuit. If circuit/connections test normal, replace the ECM.
- Test for 2.0-3.0 volts between the control circuit terminal 2 and ground.
- If the voltage is not within the specified range, replace the ECM.
- If all circuits/connections test normal, replace the IMT solenoid.
NOTE:
The control circuit for the IMT solenoid is pulled-up to voltage within the ECM, 2.0-3.0 volts on the control circuit is normal.