Circuit/System Testing
- Ignition OFF, disconnect the harness connector at the generator
- Ignition ON, test for less than 1 volt between the generator turn on signal and ground.
- If greater than the specified range, test the generator turn on signal circuit for a short to voltage. If the circuit tests normal, replace the ECM.
- With ignition ON, and the engine running, the voltage of the generator turn on signal circuit, should read over 3.5 volts.
- If less than the specified range, test the generator turn on signal circuit for a short to ground, an open or a high resistance. If the circuit tests normal, replace the ECM.
- If the circuit tests normal during the ignition ON/Run test, replace the generator.