Typical Scan Tool Data
WARNING: This page is about a different variant/trim than selected.
MAP Sensor
| Circuit |
Normal Range |
Short to Ground |
Open |
Short to Voltage |
| 5-Volt Reference |
- |
10 kPa |
10 kPa |
104 kPa |
| MAP Sensor Signal |
12-103 kPa |
10 kPa |
10 kPa |
104 kPa |
| Low Reference |
- |
- |
80-103 kPa |
- |