Removal Procedure

  1. Relieve the fuel system pressure. Refer to Fuel Pressure Relief Procedure .
    Fig 1: Blowing Dirt Out Of Fitting (Plastic Collar)
    GM155410Courtesy of GENERAL MOTORS CORP.
    CAUTION: Wear safety glasses when using compressed air in order to prevent eye injury.
  2. Blow dirt out of the fitting using compressed air.
  3. Squeeze the plastic tabs of the male end connector.
    Fig 2: Squeezing Quick Connect Fitting Release Tabs (Plastic Collar)
    GM12777Courtesy of GENERAL MOTORS CORP.
  4. Pull the connection apart.
    Fig 3: Pulling Connection Apart (Plastic Collar)
    GM12778Courtesy of GENERAL MOTORS CORP.
    NOTE: Use an emery cloth in order to remove rust or burrs from the fuel pipe. Use a radial motion with the fuel pipe end in order to prevent damage to the O-ring sealing surface.
  5. Wipe off the male pipe end using a clean shop towel.
  6. Inspect both ends of the fitting for dirt and burrs.
  7. Clean or replace the components as required.