Distributor Dual Diaphragm Vacuum Advance Unit
Using a hand-held vacuum pump, attach pump to either side of unit. Create at least 12 in. Hg vacuum with pump. Vacuum unit linkage should move. Vacuum reading on pump should remain constant. If linkage does not move or if vacuum drops, unit is defective. Repeat test procedure on other side of unit.