Power Door Lock Test 22A - Sliding Door(S) & Liftgate Fail To Lock
NOTE:
Perform POWER DOOR LOCK TEST 1A
before proceeding with this test. For connector terminal ID, see CONNECTOR IDENTIFICATION
and WIRING DIAGRAMS
. Perform TEST VER-1A - VERIFICATION PROCEDURE
after each repair.
CAUTION:
Always turn ignition switch to OFF position prior to disconnecting or connecting any module connector.
Turn ignition off. Disconnect junction block connectors "A" and "B". See Figure in CHIME TEST 2A. Using external ohmmeter, measure resistance between ground and terminal No. 25 (Brown/Light Blue wire) on connector "B". If resistance is less than 5 ohms, repair Brown/Light Blue wire for short to ground. If resistance is 5 ohms or greater, repair circuit at terminal No. 32 (Brown/Light Blue wire) on junction block connector "B" for short to ground.