Wastegate Actuator Test
Actuator is mounted on turbocharger. Apply a pressure of 9.2 psi (.65 kg/cm2 ) to wastegate actuator to ensure actuator rod moves. Do not apply more than 10.3 psi (.72 kg/cm2 ) to wastegate actuator or attempt to adjust wastegate valve.