Preliminary Procedure: "Lo-Auto"
As button is pushed, blower voltage should reduce. Rotate tester mode knob to "HEAT", the following should take place in order listed:
- Blower speed drops one step and air door goes from 20% to 100% outside air. There should be no change in discharge air temperature.
- Blower speed should decrease three further steps with an increase in discharge air temperature each time blower speed is automatically reduced one step.
- After fourth decrease in blower speed, system should automatically shift from A/C mode to Heat mode. As this occurs, blower speed should increase one step and there should be an additional rise in discharge air temperature. Move thermometer to heat outlet duct.
- In two or three minutes, blower speed should increase three more steps with an increase in discharge air temperature at each step. Final discharge air temperature should be approximately 140°F (maximum).