Circuit Operation

The normally open inlet valves are closed by application of a 12-volt signal from EBCM on pins No. 15, 17 and 35. The normally closed outlet valves are opened by application of a 12-volt signal from EBCM on pins No. 33, 34 and 16.

Fig 1: Chart G Solenoid Valves
G56192