Diagnosis Procedure
- CHECK FUSE
- Turn ignition switch OFF.
- Pull out 5 A fuse (No. 76) from IPDM E/R.
- Check that 5 A fuse is not blowing.
Is the fuse blown (open)?
YES>>
Replace the fuse after repairing the applicable circuit.
NO>>
GO TO 2.
- CHECK FUSIBLE LINK
- Turn ignition switch OFF.
- Check that the following fusible link is not blowing.
Fusible link No. Capacity No. AA 30 A
Is the fusible link blown (open)?
YES>>
Replace the fusible link after repairing the applicable circuit.
NO>>
GO TO 3.
- CHECK GROUND CONNECTION
Check ground connection F9. Refer to Ground Inspection in Circuit Inspection .
Is the inspection result normal?
YES>>
GO TO 4.
NO>>
Repair or replace error-detected parts.
- CHECK VCR CONTROL MODULE GROUND CIRCUIT
- Disconnect VCR control module harness connectors.
- Check the continuity between VCR control module harness connector and ground.
VCR control module - Continuity Connector Terminal F108 1 Ground Existed - Also check harness for short to power.
Is the inspection result normal?
YES>>
GO TO 5.
NO>>
Repair or replace error-detected parts.
- CHECK VCR CONTROL MODULE POWER SUPPLY
- Reconnect VCR control module harness connectors.
- Check the voltage between VCR control module harness connector terminals as follows.
VCR control module Voltage Connector + - Terminal F108 5 1 Battery voltage
Is the inspection result normal?
YES>>
GO TO 6.
NO>>
Perform trouble diagnosis for power supply circuit.
- CHECK IGNITION SWITCH SIGNAL
Check the voltage between VCR control module harness connectors as follows.
VCR control module Condition Voltage Connector + - Terminal Terminal F108 31 1 Ignition switch: ON Battery voltage Ignition switch: OFF 0 V Is the inspection result normal?
YES>>
Check intermittent incident. Refer to Intermittent Incident .
NO>>
GO TO 7.
- CHECK IGNITION SWITCH SIGNAL
- Turn ignition switch OFF.
- Disconnect VCR control module harness connectors.
- Disconnect IPDM E/R harness connector.
- Check the continuity between IPDM E/R harness connector and VCR control module harness connector.
IPDM E/R VCR control module Continuity Connector Terminal Connector Terminal E120 19 F108 31 Existed - Also check harness for short to power and short to ground.
Is the inspection result normal?
YES>>
Perform trouble diagnosis for power supply circuit.
NO>>
Repair or replace error-detected parts.