DTC Diagnosis Procedure
- INSPECTION START
Confirm the detected malfunction (A or B). DTC Description
Which malfunction is detected?
A>>
GO TO 2.
B>>
GO TO 7.
- CHECK HO2S2 CONNECTOR FOR WATER
- Turn ignition switch OFF.
- Disconnect heated oxygen sensor 2 harness connector.
- Check connectors for water.
Water should not exist. Is the inspection result normal?
YES>>
GO TO 3.
NO>>
Repair or replace error-detected parts.
- CHECK HO2S2 GROUND CIRCUIT
- Disconnect ECM harness connector.
- Check the continuity between HO2S2 harness connector and ECM harness connector.
+ - Continuity HO2S2 ECM Connector Terminal Connector Terminal F67 1 F71 97 Existed - Also check harness for short to power.
Is the inspection result normal?
YES>>
GO TO 4.
NO>>
Repair or replace error-detected parts.
- CHECK HO2S2 INPUT SIGNAL CIRCUIT
- Check the continuity between HO2S2 harness connector and ECM harness connector.
+ - Continuity HO2S2 ECM Connector Terminal Connector Terminal F67 2 F71 92 Existed - Check the continuity between HO2S2 harness connector and ground, or ECM harness connector and ground.
+ - Continuity HO2S2 Connector Terminal F67 2 Ground Not existed + - Continuity ECM Connector Terminal F71 92 Ground Not existed - Also check harness for short to power.
Is the inspection result normal?
YES>>
GO TO 5.
NO>>
Repair or replace error-detected parts.
- Check the continuity between HO2S2 harness connector and ECM harness connector.
- CHECK HEATED OXYGEN SENSOR 2
Check the heated oxygen sensor 2. Refer to Component Inspection .
Is the inspection result normal?
YES>>
Check intermittent incident. Refer to Intermittent Incident .
NO>>
GO TO 6.
- REPLACE HEATED OXYGEN SENSOR 2
Replace heated oxygen sensor 2. END PROCEDURE. Refer to Exploded View .
>>
INSPECTION END
- CLEAR THE MIXTURE RATIO SELF-LEARNING VALUE CLEAR
- Clear the mixture ratio self-learning value clear.
- Run engine for at least 10 minutes at idle speed.
Is the 1st trip DTC P0172 detected? Is it difficult to start engine?
YES>>
Perform trouble diagnosis for DTC P0172. DTC Description
NO>>
GO TO 8.
- CHECK HO2S2 GROUND CIRCUIT
- Turn ignition switch OFF.
- Disconnect heated oxygen sensor 2 harness connector.
- Disconnect ECM harness connector.
- Check the continuity between HO2S2 harness connector and ECM harness connector.
+ - Continuity HO2S2 ECM Connector Terminal Connector Terminal F67 1 F71 97 Existed - Also check harness for short to ground and to power.
Is the inspection result normal?
YES>>
GO TO 9.
NO>>
Repair or replace error-detected parts.
- CHECK HO2S2 INPUT SIGNAL CIRCUIT
- Check the continuity between HO2S2 harness connector and ECM harness connector.
+ - Continuity HO2S2 ECM Connector Terminal Connector Terminal F67 2 F71 92 Existed - Check the continuity between HO2S2 harness connector and ground, or ECM harness connector and ground.
+ - Continuity HO2S2 Connector Terminal F67 2 Ground Not existed + - Continuity ECM Connector Terminal F71 92 Ground Not existed - Also check harness for short to power.
Is the inspection result normal?
YES>>
GO TO 10.
NO>>
Repair open circuit or short to ground or short to power in harness or connectors.
- Check the continuity between HO2S2 harness connector and ECM harness connector.
- CHECK HEATED OXYGEN SENSOR 2
Check the heated oxygen sensor 2. Refer to Component Inspection .
Is the inspection result normal?
YES>>
Check intermittent incident. Refer to Intermittent Incident .
NO>>
GO TO 11.
- REPLACE HEATED OXYGEN SENSOR 2
Replace heated oxygen sensor 2. Refer to Exploded View .
>>
INSPECTION END