Diagnosis Procedure
- CHECK REVERSE INPUT SIGNAL
- Ignition switch ON.
- Shift the selector lever to R (reverse).
- Check voltage between AV control unit connector M131 and ground.
AV control unit
Ground
Condition
Voltage
(Approx.)
(+)
(-)
Connector
Terminal
M131
8
Selector lever is in "R".
Battery Voltage
Is inspection result normal?
YES
GO TO 2.
NO
Repair or replace harness or connectors.
- CHECK CAMERA IMAGE SIGNAL CIRCUIT CONTINUITY
- Ignition switch OFF.
- Disconnect AV control unit connector M132 and around view monitor control unit connector.
- Check continuity between AV control unit connector M132 and around view monitor control unit connector M78.COMP +
AV control unit
Around view monitor control unit
Continuity
Connector
Terminal
Connector
Terminal
M132
49
M78
4
Yes
COMP -AV control unit
Around view monitor control unit
Continuity
Connector
Terminal
Connector
Terminal
M132
48
M78
3
Yes
- Check continuity between AV control unit connector M132 and ground.
AV control unit
Ground
Continuity
Connector
Terminal
M132
49
No
Is inspection result normal?
YES
GO TO 3.
NO
Repair or replace harness or connectors.
- CHECK CAMERA IMAGE SIGNAL
- Connect AV control unit connector M132 and around view monitor control unit connector.
- Ignition switch ON.
- Shift the selector lever to R (reverse).
- Check signal between AV control unit connector M132 and ground.
AV control unit connector M132
Condition
Reference value
(+)
(-)
Terminal
Terminal
49
48
Camera image displayed.
Is inspection result normal?
YES
Replace AV control unit. Refer to AV CONTROL UNIT : Removal & Installation .
NO
Replace around view monitor control unit. Refer to AROUND VIEW MONITOR CONTROL UNIT : Removal & Installation .