Power Window Serial Link Check
- CHECK POWER WINDOW SWITCH OUTPUT SIGNAL
- Remove Intelligent Key, and close front door LH and RH.
- Check signal between BCM connector and ground with oscilloscope when door lock and unlock switch (LH and RH) is turned to "LOCK" or "UNLOCK".
- Check that signals which are shown in the figure below can be detected during 10 second just after door lock and unlock switch (LH and RH) is turned to "LOCK" or "UNLOCK".
Terminal
Signal
(Reference value)
(+)
(-)
BCM connector
Terminal
M19
54
Ground
Is the inspection result normal?
YES
Power window serial link is OK.
NO
GO TO 2 .
- CHECK POWER WINDOW SERIAL LINK CIRCUIT
- Turn ignition switch OFF.
- Disconnect BCM and main power window and door lock/unlock switch.
- Check continuity between BCM connector M19 and main power window and door lock/unlock switch connector D25.
BCM connector
Terminal
Main power window and door lock/unlock switch connector
Terminal
Continuity
M19
54
D25
11
Yes
- Check continuity between BCM connector M19 and ground.
BCM connector
Terminal
Ground
Continuity
M19
54
No
Is the inspection result normal?
YES
Replace main power window and door lock/unlock switch. Refer to Removal and Installation . After that, refer to Work Procedure .
NO
Repair or replace harness or connectors.