Diagnosis Procedure
- CHECK FUEL PUMP CONTROL MODULE POWER SUPPLY CIRCUIT-I
- Turn ignition switch OFF.
- Disconnect Fuel pump control module harness connector.
- Turn ignition switch ON.
- Check the voltage between Fuel pump control module harness connector and ground.
Fuel pump control module
Ground
Voltage
Connector
Terminal
B37
6
Ground
Battery voltage
Is the inspection result normal?
YES
GO TO 4.
NO
GO TO 2.
- CHECK FUEL PUMP CONTROL MODULE POWER SUPPLY CIRCUIT-II
- Turn ignition switch OFF.
- Disconnect IPDM E/R harness connector.
- Check the continuity between IPDM E/R harness connector and Fuel pump control module harness connector.
IPDM E/R
Fuel pump control module
Continuity
Connector
Terminal
Connector
Terminal
E121
15
B37
6
Existed
- Also check harness for short to ground and short to power.
Is the inspection result normal?
YES
GO TO 3.
NO
Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK INTERMITTENT INCIDENT
Check intermittent incident. Refer to Intermittent Incident .
Is the inspection result normal?
YES
Replace IPDM E/R. Refer to Removal and Installation .
NO
Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK FUEL PUMP CONTROL MODULE GROUND CIRCUIT FOR OPEN AND SHORT
- Turn ignition switch OFF.
- Check the continuity between Fuel pump control module harness connector and ground.
Fuel pump control module
Ground
Continuity
Connector
Terminal
B37
3
Ground
Existed
- Also check harness for short to power.
Is the inspection result normal?
YES
GO TO 5.
NO
Repair open circuit or short to power in harness or connectors.
- CHECK FUEL PUMP CONTROL MODULE INPUT AND OUTPUT CIRCUITS FOR OPEN AND SHORT
- Disconnect ECM harness connector.
- Check the continuity between Fuel pump control module harness connector and ECM harness connector.
Fuel pump control module
ECM
Continuity
Connector
Terminal
Connector
Terminal
B37
5
E32
136
Existed
4
130
- Also check harness for short to ground and short to power.
Is the inspection result normal?
YES
GO TO 6.
NO
Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK FUEL PUMP CONTROL CIRCUIT FOR OPEN AND SHORT
- Disconnect "fuel level sensor unit" harness connector.
- Check the continuity between Fuel pump control module harness connector and "fuel level sensor unit" harness connector.
Fuel pump control module
Fuel level sensor unit
Continuity
Connector
Terminal
Connector
Terminal
B37
1
B72
6
Existed
2
4
Is the inspection result normal?
YES
GO TO 7.
NO
Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK FUEL PUMP
Check fuel pump. Refer to Component Inspection(Fuel Pump) .
Is the inspection result normal?
YES
GO TO 8.
NO
Replace fuel pump. Refer to Removal and Installation .
- CHECK FUEL PUMP CONTROL MODULE
Check Fuel pump control module. Refer to Component Inspection (Fuel Pump Control Module) .
Is the inspection result normal?
YES
GO TO 9.
NO
Replace fuel pump. Refer to Removal and Installation .
- CHECK INTERMITTENT INCIDENT
Check intermittent incident. Refer to Intermittent Incident .
Repair or replace malfunctioning part.