IPDM E/R (Intelligent Power Distribution Module Engine Room): DTCIndex
|
CONSULT display |
Fail-safe |
TIME NOTE |
Refer to |
||
|
No DTC is detected. Further testing may be required. |
- |
- |
- |
- |
|
|
U1000 |
CAN COMM CIRCUIT |
? |
CRNT |
1 - 39 |
|
|
B120E |
IPDM E/R [SYSTEM INTERNAL FAILURE] |
- |
CRNT |
1 - 39 |
|
|
IPDM E/R [NOT CONFIGURED] |
|||||
|
B121A |
FR FOG LAMP LH PWR SPLY CIRC [CIRC SHORT TO GRND] |
- |
CRNT |
1 - 39 |
DTC Logic (with LED) DTC Logic (with halogen) |
|
B1231 |
DTRL RH PWR SPLY CIRC [CIRC SHORT TO GRND] |
- |
CRNT |
1 - 39 |
DTC Logic (with LED) DTC Logic (with halogen) |
|
B1256 |
FR FOG LAMP RH PWR SPLY CIRC [CIRC SHORT TO GRND] |
- |
CRNT |
1 - 39 |
DTC Logic (with LED) DTC Logic (with halogen) |
|
B20A9 |
STARTER RELAY EXTERNAL FAILURE [CIRC OPEN] |
- |
CRNT |
1 - 39 |
|
|
B20CB |
DTRL LH PWR SPLY CIRC [CIRC SHORT TO GRND] |
- |
CRNT |
1 - 39 |
DTC Logic (with LED) DTC Logic (with halogen) |
|
B20CE |
HL (HI) LH PWR SPLY CIRC [CIRC SHORT TO GRND] |
- |
CRNT |
1 - 39 |
DTC Logic (with LED) DTC Logic (with halogen) |
|
B20CF |
HL (HI) RH PWR SPLY CIRC [CIRC SHORT TO GRND] |
- |
CRNT |
1 - 39 |
DTC Logic (with LED) DTC Logic (with halogen) |
|
B20D0 |
HL (LO) LH PWR SPLY CIRC [CIRC SHORT TO GRND] |
- |
CRNT |
1 - 39 |
DTC Logic (with LED) DTC Logic (with halogen) |
|
B20D1 |
HL (LO) RH PWR SPLY CIRC [CIRC SHORT TO GRND] |
- |
CRNT |
1 - 39 |
DTC Logic (with LED) DTC Logic (with halogen) |
|
B20D2 |
PARKING LAMP PWR SPLY CIRC [CIRC SHORT TO GRND] |
- |
CRNT |
1 - 39 |
DTC Logic (with LED) DTC Logic (with halogen) |
|
B20D4 |
TAIL LAMP LH PWR SPLY CIRC [CIRC SHORT TO GRND] |
- |
CRNT |
1 - 39 |
DTC Logic (with LED) DTC Logic (with halogen) |
|
B20D5 |
TAIL LAMP RH PWR SPLY CIRC [CIRC SHORT TO GRND] |
- |
CRNT |
1 - 39 |
DTC Logic (with LED) DTC Logic (with halogen) |
|
B20E3 |
LED HEADLAMP LH [CMPNENT INTERNAL MLFNCTN] |
- |
CRNT |
1 - 39 |
|
|
B20E2 |
LED HEADLAMP RH [CMPNENT INTERNAL MLFNCTN] |
- |
CRNT |
1 - 39 |
|
|
B20DD |
IGN RELAY ON CIRC [CIRC SHORT TO BATTERY] |
? |
CRNT |
1 - 39 |
|
|
B20DE |
IGN RELAY OFF CIRC [CIRC SHORT TO GROUND OR OPEN] |
- |
CRNT |
1 - 39 |
|
|
B20DF |
STARTER RELAY OFF STUCK [CIRC SHORT TO GROUND OR OPEN] |
- |
CRNT |
1 - 39 |
|
|
B210D |
STARTER RELAY ON STUCK [ACTUATOR STUCK OPEN] |
- |
CRNT |
1 - 39 |
|
|
B20A1 |
ECM RELAY ON CIRCUIT [CIRC SHORT TO BATTERY] |
- |
CRNT |
1 - 39 |
|
- CRNT: The malfunctions that are detected now
- 1 - 39: The number is indicated when it is normal at present and a malfunction was detected in the past. It increases like 0 → 1 → 2... 38 → 39 after returning to the normal condition whenever IGN OFF → ON. It is fixed to 39 until the self-diagnosis results are erased if it is over 39. It returns to 0 when a malfunction is detected again in the process.