Diagnostic Test
- CHECK FUSE
- Turn ignition switch OFF.
- Check that the following fuse is not blowing.
Location Fuse No. Capacity IPDM E/R #47 15A
Is the fuse blown (open)?
YES
Replace the fuse after repairing the applicable circuit.
NO
GO TO STEP 2 .
- CHECK FPCM POWER SUPPLY
- Turn ignition switch OFF.
- Disconnect FPCM harness connector.
- Turn ignition switch ON.
- Check the voltage between FPCM harness connector and ground.
+ - Voltage FPCM Connector Terminal B58 6 Ground Battery voltage
Is the inspection result normal?
YES
GO TO STEP 4 .
NO
GO TO STEP 3 .
- CHECK FPCM POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Disconnect IPDM E/R harness connector.
- Check the continuity between FPCM harness connector and IPDM E/R harness connector.
FPCM IPDM E/R Continuity Connector Terminal Connector Terminal B58 6 E121 15 Existed - Also check harness for short to power and short to ground.
Is the inspection result normal?
YES
Perform trouble diagnosis for power supply circuit.
NO
Repair or replace error-detected parts.
- CHECK FPCM GROUND CIRCUIT
- Turn ignition switch OFF.
- Check the continuity between FPCM harness connector and ground.
FPCM - Continuity Connector Terminal B58 3 Ground Existed - Also check harness for short to power.
Is the inspection result normal?
YES
GO TO STEP 5 .
NO
Repair or replace error-detected parts.
- CHECK FPCM INPUT AND OUTPUT CIRCUIT
- Disconnect ECM harness connector.
- Check the continuity between FPCM harness connector and ECM harness connector.
FPCM ECM Continuity Connector Terminal Connector Terminal B58 4 E32 182 Existed 5 188 - Also check harness for short to power and short to ground.
Is the inspection result normal?
YES
GO TO STEP 6 .
NO
Repair or replace error-detected parts.
- CHECK FUEL PUMP CONTROL CIRCUIT
- Disconnect "fuel level sensor unit and fuel pump (main)" harness connector.
- Check the continuity between FPCM harness connector and "fuel level sensor unit and fuel pump (main)" harness connector.
FPCM Fuel level sensor unit and fuel pump (main) Continuity Connector Terminal Connector Terminal B58 1 B72 6 Existed 2 4 - Also check harness for short to power and short to ground.
Is the inspection result normal?
YES
GO TO STEP 7 .
NO
Repair or replace error-detected parts.
- CHECK FPCM
Refer to COMPONENT INSPECTION (FPCM) .
Is the inspection result normal?
YES
INSPECTION END
NO
Replace FPCM. Refer to REMOVAL AND INSTALLATION .