Mike's Workshop Manuals: Service manuals for every vehicle
Home >> Nissan-Datsun >> 2017 >> Maxima SL >> Repair and Diagnosis >> Engine Performance >> System >> Engine Control System (DTCS) (3 Of 4) >> DTC/Circuit Diagnosis >> DTC P0451: EVAP Control System Pressure Sensor >> Diagnosis Procedure >> Diagnostic Test

Diagnostic Test

  1. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR CONNECTOR FOR WATER

    1. Disconnect EVAP control system pressure sensor harness connector.
    2. Check that water is not inside connectors.

    Is the inspection result normal?

    YES 

    GO TO STEP 2  .

    NO 

    Repair or replace error-detected parts.

  2. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY

    1. Turn ignition switch ON.
    2. Check the voltage between EVAP control system pressure sensor harness connector and ground.
      + - Voltage (V)
      EVAP control system pressure sensor
      Connector Terminal
      B41 3 Ground Approx. 5

    Is the inspection result normal?

    YES 

    GO TO STEP 4. 

    NO 

    GO TO STEP 3. 

  3. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY CIRCUIT

    1. Turn ignition switch OFF.
    2. Disconnect ECM harness connector.
    3. Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.
      EVAP control system pressure sensor ECM Continuity
      Connector Terminal Connector Terminal
      B41 3 E10 125 Existed

    Is the inspection result normal?

    YES 

    INSPECTION END

    NO 

    Repair or replace error-detected parts.

  4. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR GROUND CIRCUIT

    1. Turn ignition switch OFF.
    2. Disconnect ECM harness connector.
    3. Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.
      EVAP control system pressure sensor ECM Continuity
      Connector Terminal Connector Terminal
      B41 1 E10 148 Existed
    4. Also check harness for short to ground and short to power.

    Is the inspection result normal?

    YES 

    GO TO STEP 5  .

    NO 

    Repair or replace error-detected parts.

  5. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR

    Check EVAP control system pressure sensor. Refer to COMPONENT INSPECTION .

    Is the inspection result normal?

    YES 

    INSPECTION END

    NO 

    Replace EVAP control system pressure sensor. Refer to REMOVAL AND INSTALLATION .