Diagnostic Test
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR CONNECTOR FOR WATER
- Disconnect EVAP control system pressure sensor harness connector.
- Check that water is not inside connectors.
Is the inspection result normal?
YES
GO TO STEP 2 .
NO
Repair or replace error-detected parts.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY
- Turn ignition switch ON.
- Check the voltage between EVAP control system pressure sensor harness connector and ground.
+ - Voltage (V) EVAP control system pressure sensor Connector Terminal B41 3 Ground Approx. 5
Is the inspection result normal?
YES
GO TO STEP 4.
NO
GO TO STEP 3.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.
EVAP control system pressure sensor ECM Continuity Connector Terminal Connector Terminal B41 3 E10 125 Existed
Is the inspection result normal?
YES
INSPECTION END
NO
Repair or replace error-detected parts.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR GROUND CIRCUIT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.
EVAP control system pressure sensor ECM Continuity Connector Terminal Connector Terminal B41 1 E10 148 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES
GO TO STEP 5 .
NO
Repair or replace error-detected parts.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR
Check EVAP control system pressure sensor. Refer to COMPONENT INSPECTION .
Is the inspection result normal?
YES
INSPECTION END
NO
Replace EVAP control system pressure sensor. Refer to REMOVAL AND INSTALLATION .