Diagnostic Test
- PRECONDITIONING
TESTING CONDITION:
- Before performing the following procedure, confirm that battery voltage is more than 12.8 V at idle.
- Before performing the following procedure, confirm that all load switches and A/C switch are turned OFF.
GO TO STEP 2 .
- PERFORM COMPONENT FUNCTION CHECK
With CONSULT
- Start engine and let it idle.
- Select "BAT CUR SEN" in "DATA MONITOR" mode of "ENGINE" using CONSULT.
- Check "BAT CUR SEN" indication for 10 seconds.
"BAT CUR SEN" should be above 2, 300 mV at least once.
Without CONSULT
- Start engine and let it idle.
- Check the voltage between ECM harness connector and ground.
ECM Voltage Connector + - Terminal F23 38 43 Above 2.3 V at least once
Is the inspection result normal?
YES
INSPECTION END
NO
Proceed to DIAGNOSIS PROCEDURE .