Front Power Window Motor LH Circuit Check
- CHECK MAIN POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH OUTPUT SIGNAL
- Turn ignition switch OFF.
- Disconnect front power window motor LH.
- Turn ignition switch ON.
- Check voltage between front power window motor LH connector D8 and ground.
Terminal Main power window and door lock/unlock switch condition Voltage
(Approx.)(+) (-) Front power window motor LH connector Terminal D8 1 Ground UP Battery voltage DOWN 0 3 UP 0 DOWN Battery voltage
Is the inspection result normal?
YES
GO TO STEP 3 .
NO
GO TO STEP 2 .
- CHECK HARNESS CONTINUITY
- Turn ignition switch OFF.
- Disconnect main power window and door lock/unlock switch.
- Check continuity between main power window and door lock/unlock switch connector D11 and front power window motor LH connector D8.
Main power window and door lock/unlock switch
connectorTerminal Front power window motor LH connector Terminal Continuity D11 17 D8 1 Yes 19 3 - Check continuity between main power window and door lock/unlock switch connector D11 and ground.
Main power window and door lock/unlock switch connector Terminal Ground Continuity D11 17 No 19
Is the inspection result normal?
YES
Replace main power window and door lock/unlock switch. Refer to REMOVAL AND INSTALLATION . After that, refer to WORK PROCEDURE .
NO
Repair or replace harness.
- CHECK FRONT POWER WINDOW MOTOR LH
Check front power window motor LH.
Refer to COMPONENT INSPECTION .
Is the inspection result normal?
YES
Check intermittent incident. Refer to INTERMITTENT INCIDENT .
NO
Replace front power window motor LH. Refer to REMOVAL AND INSTALLATION . After that, refer to WORK PROCEDURE .