Consult Function (Occupant Detection)
CAUTION:
After disconnecting the CONSULT vehicle interface (VI) from the data link connector, the ignition must be cycled OFF → ON (for at least 5 seconds) → OFF. If this step is not performed, the BCM may not go to "sleep mode", potentially causing a discharged battery and a no-start condition.
CONSULT can display each diagnostic item using the diagnostic test modes shown following.
| Diagnostic Test Mode | Diagnostic Item | Description |
|---|---|---|
| Work support | ZERO POINT RESET FUNCTION | Perform zero point reset. Refer to SPECIAL REPAIR REQUIREMENT . |