Inspection Procedure
- CHECK REAR VIEW CAMERA WASHER/AIR BLOWER FUNCTION
- Start the engine.
- Select the "Active Test" item "AIR&WASH ACTIVE" of "AVM" using CONSULT.NOTE:
Before function check, perform the following items:
- Fill with washer fluid.
- Perform "Active Test" item "WASH ACTIVE" of "AVM" using CONSULT for 4 seconds.
- While operating the test item, check the operation.
Is it properly operated?
Washer fluid ejects 4 - 6 times. (Normal function)
Inspection End.
Washer fluid ejects 7 times or more.
Properly install or replace air tube.
Washer fluid ejects only once
Properly install or replace air tube.
Washer fluid does not eject
Properly install washer tube or replace washer tube and check valve.