Quick Charge Does Not Start

Symptom Possible cause Action
Quick charge does not start. Quick charge start conditions are not satisfied. VCM recognizes that the selector lever is in a range other than P range. Electric shift system error. Perform self-diagnosis of electric shift control module.
- Power switch is not OFF. Normal operation.
- VCM receives a charge stop request signal from PDM (Power Delivery Module). Check that charging condition is normal.
VCM recognizes that the quick charge connector and the normal charge connector are simultaneously connected. Abnormal connection detection circuit of normal charge port. Check normal charge port.
Abnormal PDM (Power Delivery Module). Perform self-diagnosis of PDM (Power Delivery Module).
VCM prohibits charging. Fail-safe of VCM. FAIL-SAFE
VCM recognizes that the quick charge connector is not connected. Abnormal connection detection circuit of quick charge port. Check quick charge port.
Abnormal PDM (Power Delivery Module). Perform self-diagnosis of PDM (Power Delivery Module).
Quick charger does not permit quick charge. Quick charger detects insulation resistance degradation in high voltage circuit. Insulation resistance degradation between PDM (Power Delivery Module) and quick charger.
  • Check PDM (Power Delivery Module).
  • Check high voltage harness.
  • Check quick charge port.
  • Check quick charger.