Normal Charge Does Not Start
| Symptom | Possible cause | Action | ||
|---|---|---|---|---|
| Normal charge does not start. | Normal charge start conditions are not satisfied. | VCM recognizes that the selector lever is in a range other than P range. | Electric shift system error. | Perform self-diagnosis of Electric shift control module. |
| - | Power switch is not OFF. | Normal operation. | ||
| - | VCM receives a charge stop request signal from PDM (Power Delivery Module). | Check to see if charge stop conditions are satisfied. Refer to NORMAL CHARGE CONTROL . | ||
| VCM recognizes that quick charge connector and normal charge connector are connected simultaneously. | Abnormal connection detection circuit of quick charge port. | Check quick charge port. | ||
| Abnormal PDM (Power Delivery Module). | Perform self-diagnosis of PDM (Power Delivery Module). | |||
| VCM prohibits charging. | Fail-safe of VCM. | FAIL-SAFE | ||
| VCM recognizes that normal charge connector is not connected. | Abnormal connection detection circuit of normal charge port. | Check normal charge port. | ||
| Abnormal PDM (Power Delivery Module). | Perform self-diagnosis of PDM (Power Delivery Module). | |||
| VCM recognizes that a PWM signal is not received from EVSE. | AC power, no input. (Disconnect from outlet) |
Check outlet. | ||
| AC power, no input. (Blackout) |
Check AC power. | |||
| EVSE does not transmit a PWM signal. | Perform self-diagnosis of PDM (Power Delivery Module). | |||
| Abnormal PDM (Power Delivery Module). | ||||
| - | Timer charge is set. |
|
||
| Judged as fully-charged. | - | Li-ion battery is fully charged. | Normal operation. | |
| Symptom | Possible cause | Action | ||
|---|---|---|---|---|
| Normal charge does not start. | EVSE does not activate. | EVSE detects electric leakage |
|
|
| EVSE has a malfunction | Plug EVSE alone into an outlet (AC source) and check that the "Fault"
lamp of EVSE does not turn ON
. If the lamp turns ON, replace EVSE. |
|||
| EVSE not energized | Plug EVSE alone into an outlet (AC source) and check that the "Ready"
lamp of EVSE turns ON
. If the lamp does not turn ON, replace EVSE. |
|||
| EVSE communication line has a malfunction | Plug EVSE alone into an outlet (AC source) and check that the "Fault"
lamp on EVSE does not blink
. If the lamp blinks, replace EVSE. |
|||