Diagnosis Procedure
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR CONNECTOR FOR WATER
- Turn ignition switch OFF.
- Disconnect EVAP control system pressure sensor harness connector.
- Check sensor harness connector for water.
Water should not exist.
Is the inspection result normal?
YES: GO TO 2.
NO: Repair or replace harness connector.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY
- Turn ignition switch ON.
- Check the voltage between EVAP control system pressure sensor harness connector and ground.
EVAP control system pressure sensor Ground Voltage (Approx.) Connector Terminal B3 3 Ground 5 V Is the inspection result normal?
YES: GO TO 6.
NO: GO TO 3.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.
EVAP control system pressure sensor ECM Continuity Connector Terminal Connector Terminal B3 3 F11 71 Existed - Also check harness for short to ground and to power.
Is the inspection result normal?
YES: GO TO 4.
NO: Repair or replace error-detected parts
- CHECK SENSOR POWER SUPPLY CIRCUIT
Check harness for short to power and short to ground, between the following terminals.
ECM Sensor Connector Terminal Name Connector Terminal F11 71 EVAP control system pressure sensor B3 3 Battery current sensor F9 1 75 CKP sensor (POS) F15 1 E16 101 Refrigerant pressure sensor(1) E17 3 102 Accelerator pedal position sensor 2 E12 5 (1) With A/C models Is the inspection result normal?
YES: GO TO 5.
NO: Repair short to ground or short to power in harness or connectors.
- CHECK COMPONENTS
Check the following.
- Battery current sensor (Refer to "COMPONENT INSPECTION ").
- CKP sensor (POS) (Refer to "COMPONENT INSPECTION ").
- Refrigerant pressure sensor (Refer to "COMPONENT FUNCTION CHECK ").
- Accelerator pedal position sensor (Refer to
"COMPONENT INSPECTION ").
Is the inspection result normal?
YES: Check intermittent incident. Refer to "INTERMITTENT INCIDENT ".
NO: Replace malfunctioning component.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR GROUND CIRCUIT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.
EVAP control system pressure sensor ECM Continuity Connector Terminal Connector Terminal B3 1 F11 68 Existed - Also check harness for short to power.
Is the inspection result normal?
YES: GO TO 7.
NO: Repair or replace error-detected parts.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR SIGNAL CIRCUIT
- Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.
EVAP control system pressure sensor ECM Continuity Connector Terminal Connector Terminal B3 2 F11 43 Existed - Also check harness for short to ground and to power.
Is the inspection result normal?
YES: GO TO 8.
NO: Repair or replace error-detected parts.
- Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR
Check the EVAP control system pressure sensor. Refer to "COMPONENT INSPECTION ".
Is the inspection result normal?
YES: Check intermittent incident. Refer to "INTERMITTENT INCIDENT ".
NO: Replace EVAP control system pressure sensor. Refer to "REMOVAL AND INSTALLATION ".