Physical Values

Terminal No. (Wire color) Description Condition Voltage (Approx.)
+ - Signal name Input/Output
1 (B) Ground Ground - - 0
2 (LA/GR) 16 (LA/SB) Front power window motor RH DOWN signal Output When front RH switch in power window main switch is operated DOWN. Battery voltage
4 (R) 12 (Y) Encoder pulse signal 2 Input When power window motor operates.
G04888494
5 (W) 12 (Y) Encoder pulse signal 1 Input When power window motor operates.
G04888494
6 (P) Ground Rear power window motor RH DOWN signal Output When rear RH switch in power window main switch is operated DOWN. Battery voltage
7 (LG) Ground Rear power window motor RH UP signal Output When rear RH switch in power window main switch is operated UP. Battery voltage
8 (LA/Y) Ground Rear power window motor LH DOWN signal Output When rear LH switch in power window main switch is operated DOWN. Battery voltage
9 (LA/W) Ground Rear power window motor LH UP signal Output When rear LH switch in power window main switch is operated UP. Battery voltage
10 (SB) Ground RAP signal Input IGN SW ON Battery voltage
Within 45 second after ignition switch is turned to OFF. Battery voltage
When driver side or passenger side door is opened during retained power operation. 0
12 (Y) Ground Encoder ground - - 0
14 (G) Ground Encoder power supply Output When ignition switch ON or power window timer operates. 10
16 (LA/SB) 2 (LA/GR) Front power window motor RH UP signal Output When front RH switch in power window main switch is operated UP. Battery voltage
17 (LA/L) 19 (LA/BR) Front power window motor LH UP signal Output When front LH switch in power window main switch is operated UP. Battery voltage
18 (LA/R) Ground Battery power supply Input - Battery voltage
19 (LA/BR) 17 (LA/L) Front power window motor LH DOWN signal Output When front LH switch in power window main switch is operated DOWN. Battery voltage