Inspection Procedure
- CHECK REAR VIEW CAMERA WASHER/AIR BLOWER FUNCTION
- Start the engine.
- Select the "Active Test" item "AIR&WASH ACTIVE" of "AVM" with CONSULT.NOTE: Before function check, perform the following items:
- Fill with washer fluid.
- Perform "Active Test" item "WASH ACTIVE" of "AVM" with CONSULT for 4 seconds.
- While operating the test item, check the operation.
Is it properly operated?
Washer fluid ejects 4 - 6 times. (Normal function): Inspection End.
Washer fluid ejects 7 times or more.: Properly install or replace air tube.
Washer fluid ejects only once: Properly install or replace air tube.