VCM stops the normal charging when VCM detects the EVSE is disconnected.
In addition, under the following conditions, VCM temporarily stops the normal charging and enters standby status.
- When the AC voltage and PWM communication from the EVSE are interrupted.
- When the EVSE connector release switch is pressed.
- When the Li-ion battery temperature reaches 60°C (140°F) or higher.