Front Power Window Motor LH Circuit Check
- CHECK MAIN POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH OUTPUT SIGNAL
- Turn ignition switch OFF.
- Disconnect front power window motor LH.
- Turn ignition switch ON.
- Check voltage between front power window motor LH connector D8 and ground.
Terminal Main power window and door lock/unlock switch condition Voltage (Approx.) (+) (-) Front power window motor LH connector Terminal D8 1 Ground UP Battery voltage DOWN 0 3 UP 0 DOWN Battery voltage Is the inspection result normal?
YES: GO TO 3.
NO: GO TO 2.
- CHECK HARNESS CONTINUITY
- Turn ignition switch OFF.
- Disconnect main power window and door lock/unlock switch.
- Check continuity between main power window and door lock/unlock switch connector D11 and front power window motor LH connector D8.
Main power window and door lock/unlock switch connector Terminal Front power window motor LH connector Terminal Continuity D11 17 D8 1 Yes 19 3 - Check continuity between main power window and door lock/unlock switch connector D11 and ground.
Main power window and door lock/unlock switch connector Terminal Ground Continuity D11 17 No 19 Is the inspection result normal?
YES: Replace main power window and door lock/unlock switch. Refer to "REMOVAL AND INSTALLATION ". After that, refer to "WORK PROCEDURE ".
NO: Repair or replace harness.
- CHECK FRONT POWER WINDOW MOTOR LH
Check front power window motor LH.
Refer to "DRIVER SIDE: COMPONENT INSPECTION ".
Is the inspection result normal?
YES: Check intermittent incident. Refer to "INTERMITTENT INCIDENT ".
NO: Replace front power window motor LH. Refer to "REMOVAL AND INSTALLATION ". After that, refer to "WORK PROCEDURE ".