Main Power Window and Door Lock/Unlock Switch Power Supply and Ground Circuit Inspection
- CHECK POWER SUPPLY CIRCUIT
- Turn ignition switch ON.
- Check voltage between main power window and door lock/unlock switch connector D5 terminal 10, D11 terminal 19 and ground.
10 - Ground: Battery voltage
19 - Ground: Battery voltage
OK or NG
OK: GO TO 2.
NG: GO TO 3.
- CHECK GROUND CIRCUIT
- Turn ignition switch OFF.
- Disconnect main power window and door lock/unlock switch.
- Check continuity between main power window and door lock/unlock switch connector and ground.
Connector Terminals Continuity D5 17 Ground Yes OK or NG
OK: Power supply and ground circuit are OK.
NG: Repair or replace harness.
- CHECK MAIN POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Disconnect BCM and main power window and door lock/unlock switch.
- Check continuity between BCM connector (A) and main power window and door lock/unlock switch connector (B).
Connector Terminal Connector Terminal Continuity A B M20 68 D5 10 Yes 69 C 19 Yes D11 - Check continuity between BCM connector (A) and ground.
Connector Terminal Ground Continuity A M20 68 No 69 No OK or NG
OK: GO TO 4.
NG: Repair or replace harness.
- CHECK BCM OUTPUT SIGNAL
- Connect BCM.
- Turn ignition switch ON.
- Check voltage between BCM connector M20 terminal 68, 69 and ground.
68 - Ground: Battery voltage
69 - Ground: Battery voltage
OK or NG
OK: Check the condition of the harness and the connector.
NG: Replace BCM. Refer to , "REMOVAL AND INSTALLATION OF BCM ".