| 3 (W) |
Ground |
ENCODER SIG1 |
Input |
When power window motor operates. |
|
| 4 (R) |
Ground |
ENCODER POWER |
Output |
When ignition switch ON or power window timer operates. |
10V |
| 7 (B) |
Ground |
ENCODER GND |
- |
- |
0 |
| 8 (R) |
Ground |
DR UP |
Output |
Main power window and door lock/unlock switch driver side switch is operated UP |
Battery voltage |
| 9 (L) |
Ground |
BAT (+) |
Input |
- |
Battery voltage |
| 10 (B) |
Ground |
GND |
- |
- |
0 |
| 11 (Y) |
Ground |
DR DOWN |
Output |
Main power window and door lock/unlock switch driver side switch is operated DOWN |
Battery voltage |
| 13 (W) |
Ground |
RAP signal |
Input |
IGN SW ON |
Battery voltage |
| Within 45 second after ignition switch is turned to OFF. |
Battery voltage |
| When front LH or RH door is opened during retained power operation. |
0 |
| 14 (V) |
Ground |
PASS UP |
Output |
Main power window and door lock/unlock switch passenger side switch is operated UP |
Battery voltage |
| 15 (G) |
Ground |
PASS DN |
Output |
Main power window and door lock/unlock switch passenger side switch is operated DOWN |
Battery voltage |