Component Inspection
- CHECK VIAS CONTROL SOLENOID VALVE 2
With CONSULT
- Turn ignition switch OFF.
- Reconnect all harness connectors disconnected.
- Disconnect vacuum hoses connected to VIAS control solenoid valve 2.
- Turn ignition switch ON.
- Select "VIAS S/V-2" in "ACTIVE TEST" mode with CONSULT.
- Check air passage continuity and operation delay time under the following conditions.
Condition (VIAS S/V 2) Air passage continuity between (A) and (B) Air passage continuity between (A) and (C) ON Existed Not existed OFF Not existed Existed
Without CONSULT
- Turn ignition switch OFF.
- Disconnect VIAS control solenoid valve 2 harness connector.
- Disconnect vacuum hoses connected to VIAS volume control solenoid valve 2.
- Check air passage continuity and operation delay time under the following conditions.
Condition Air passage continuity between (A) and (B) Air passage continuity between (A) and (C) 12 V direct current supply between terminals 1 and 2 Existed Not existed No supply Not existed Existed Courtesy of NISSAN NORTH AMERICA, INC.
Is the inspection result normal?
YES: INSPECTION END
NO: Replace VIAS control solenoid valve 2