Home >> Nissan-Datsun >> 2012 >> Leaf SL >> Repair and Diagnosis >> Hybrid/Electric Powertrain >> Electric Converters and Controllers >> EV Control System >> System Description >> System >> Automatic 12V Battery Charge Control >> AUTOMATIC 12V BATTERY CHARGE CONTROL: System Description >> Control Description

Control Description

Power ON

VCM monitors the 12V battery voltage during POWER ON cycle and immediately starts charging when VCM judges that the voltage is lowered.

NOTE: VCM does not perform the automatic 12V battery charge control when the shift position is in a range other than "P" range.

When Vehicle is Not Used for A Long Time

VCM measures the time of no operation using its internal timer. If the time of no operation reaches 120 hours, VCM performs automatic charge for 5 minutes.

VCM resets the no operation status continuous time when the vehicle satisfies one of the following conditions.