Inspection Procedure
- SELF-DIAGNOSIS RESULT CHECK
Check the self-diagnosis results.
SELF-DIAGNOSIS RESULTSSelf-diagnosis results ST ANG SEN COM CIR CAN COMM CIRCUIT Is the above displayed in the self-diagnosis display items?
YES: GO TO 2.
NO: Inspection End.
- CHECK CONNECTOR
- Disconnect the ABS actuator and electric unit (control unit) connector, and check the terminals for deformation, disconnection, looseness, and so on. If there is a malfunction, repair or replace the terminals.
- Reconnect connector to perform self-diagnosis. Refer to
"CONSULT-III FUNCTION (ABS) ".
Is "CAN COMM CIRCUIT" displayed in the self-diagnosis display items?
YES: Refer to "TROUBLE DIAGNOSIS FLOW CHART ".
NO: Connector terminal connection is loose, damaged, open, or shorted.