Inspection Procedure
- SELF-DIAGNOSIS RESULT CHECK
Check self-diagnosis results.
SELF-DIAGNOSIS RESULT REFERENCESelf-diagnosis results BATTERY VOLTAGE Is the above displayed in the self-diagnosis display items?
YES: GO TO 2.
NO: Inspection End.
- CONNECTOR INSPECTION
- Disconnect the ABS actuator and electric unit (control unit) connector.
- Check the terminals for deformation, disconnection, looseness or damage.
OK or NG
OK: GO TO 3.
NG: Repair or replace as necessary.
- ABS/TCS/VDC CONTROL UNIT POWER AND GROUND CIRCUIT INSPECTION
Measure the voltage and continuity between the ABS actuator and electric unit (control unit) connector E33 and ground.
ABS ACTUATOR AND ELECTRIC UNIT SPECIFICATIONSignal name ABS actuator and electric unit (control unit) connector E33 Ground Measured value Power supply 2 - Battery voltage (Approx. 12V) 3 Ground 1 Continuity should exist. 4 OK or NG
OK: Check the battery for loose terminals, low voltage, etc. Repair as necessary.
NG: Repair the circuit.