Component Inspection
- CHECK SECURITY INDICATOR LAMP
- Disconnect security indicator lamp connector.
- Check continuity between security indicator lamp terminals.
CONTINUITY SPECIFICATIONTerminal Continuity Security indicator lamp (+) (-) 1 2 Existed 2 1 Not existed Is the inspection result normal?
YES: INSPECTION END
NO: Replace security indicator lamp. Refer to "REMOVAL AND INSTALLATION ".