Diagnosis Procedure
- CHECK IGNITION SWITCH OUTPUT SIGNAL (PUSH-BUTTON IGNITION SWITCH)
- Disconnect push-button ignition switch connector and IPDM E/R connector.
- Check voltage between push-button ignition switch harness connector and ground.
VOLTAGE REFERENCE CHART(+) (-) Voltage (V) (Approx.) Push-button ignition switch Connector Terminal M101 8 Ground 12 Is the inspection result normal?
YES: GO TO 3.
NO: GO TO 2.
- CHECK PUSH-BUTTON IGNITION SWITCH CIRCUIT (BCM)
- Disconnect BCM connector.
- Check continuity between BCM harness connector and push-button ignition switch harness connector.CONTINUITY REFERENCE CHART
BCM Push-button ignition switch Continuity Connector Terminal Connector Terminal M71 100 M101 8 Existed - Check continuity between push-button ignition switch harness connector and ground.
CONTINUITY REFERENCE CHARTPush-button ignition switch Ground Continuity Connector Terminal M101 8 Not existed Is the inspection result normal?
YES: Replace BCM. Refer to "REMOVAL AND INSTALLATION ".
NO: Repair or replace harness.
- CHECK IGNITION SWITCH OUTPUT SIGNAL (IPDM E/R)
Check voltage between IPDM E/R harness connector and ground.
VOLTAGE REFERENCE CHART(+) (-) Voltage (V) (Approx.) IPDM E/R Connector Terminal E17 66 Ground 12 Is the inspection result normal?
YES: Replace IPDM E/R. Refer to "REMOVAL AND INSTALLATION ".
NO: GO TO 4.
- CHECK PUSH-BUTTON IGNITION SWITCH CIRCUIT (IPDM E/R)
- Disconnect IPDM E/R connector.
- Check continuity between IPDM E/R harness connector and push-button ignition switch harness connector.CONTINUITY REFERENCE CHART
IPDM E/RPush-button ignition switch Continuity Connector Terminal Connector Terminal E17 66 M101 8 Existed - Check continuity between push-button ignition switch harness connector and ground.
CONTINUITY REFERENCE CHARTPush-button ignition switch Ground Continuity Connector Terminal M101 8 Not existed Is the inspection result normal?
YES: GO TO 5.
NO: Repair or replace harness.
- CHECK INTERMITTENT INCIDENT
Refer to "INTERMITTENT INCIDENT ".
INSPECTION END