Diagnosis Procedure
- INSPECTION START
Start engine.
Is engine running?
YES: GO TO 8.
NO: GO TO 2.
- CHECK ECM POWER SUPPLY CIRCUIT-I
- Turn ignition switch OFF and then ON.
- Check the voltage between ECM harness connector and ground.TERMINALS VOLTAGE REFERENCE
ECM Ground Voltage Connector Terminal E16 93 Ground Battery voltage
Is the inspection result normal?
YES: GO TO 4.
NO: GO TO 3.
- DETECT MALFUNCTIONING PART
Check the following.
- IPDM E/R harness connector E14
- 15A fuse (No. 64)
- Harness for open or short between ECM and fuse
Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK GROUND CONNECTION-I
- Turn ignition switch OFF.
- Check ground connection E21. Refer to Ground Inspection in "CIRCUIT INSPECTION ".
Is the inspection result normal?
YES: GO TO 5.
NO: Repair or replace ground connection.
- CHECK ECM GROUND CIRCUIT FOR OPEN AND SHORT-I
- Disconnect ECM harness connectors.
- Check the continuity between ECM harness connector and ground.TERMINALS CONTINUITY REFERENCE
ECM Ground Continuity Connector Terminal F7 12 Ground Existed 16 E16 107 108 111 112 - Also check harness for short to power.
Is the inspection result normal?
YES: GO TO 7.
NO: GO TO 6.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors F121, E7
- Harness for open or short between ECM and ground
Repair open circuit or short to power in harness or connectors.
- CHECK ECM POWER SUPPLY CIRCUIT-II
- Reconnect ECM harness connectors.
- Turn ignition switch ON.
- Check the voltage between IPDM E/R harness connector and ground.TERMINALS VOLTAGE REFERENCE
IPDM E/R Ground Voltage Connector Terminal E15 47 Ground Battery voltage
Is the inspection result normal?
YES: GO TO "DIAGNOSIS PROCEDURE ".
NO: GO TO 8.
- CHECK ECM POWER SUPPLY CIRCUIT-III
- Turn ignition switch OFF and wait at least 10 seconds.
- Check the voltage between ECM harness connector and ground.TERMINALS VOLTAGE REFERENCE
ECM Ground Voltage Connector Terminal E16 105 Ground After turning ignition switch OFF, battery voltage will exist for a few seconds, then drop approximately 0 V.
Is the inspection result normal?
YES: GO TO 14.
NO-1: Battery voltage does not exist: GO TO 9.
NO-2: Battery voltage exists for more than a few seconds: GO TO 11.
- CHECK ECM POWER SUPPLY CIRCUIT-IV
- Turn ignition switch OFF and wait at least 10 seconds.
- Check the voltage between ECM harness connector and ground.TERMINALS VOLTAGE REFERENCE
ECM Ground Voltage Connector Terminal F7 24 Ground Battery voltage
Is the inspection result normal?
YES: GO TO 10.
NO: GO TO 11.
- CHECK ECM POWER SUPPLY CIRCUIT-V
- Disconnect ECM harness connector.
- Disconnect IPDM E/R harness connector E15.
- Check the continuity between ECM harness connector and IPDM E/R harness connector.TERMINALS CONTINUITY REFERENCE
ECM IPDM E/R Continuity Connector Terminal Connector Terminal E16 105 E15 48 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES: GO TO 17.
NO: Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK ECM POWER SUPPLY CIRCUIT-VI
- Disconnect ECM harness connector.
- Disconnect IPDM E/R harness connector E15.
- Check the continuity between ECM harness connector and IPDM E/R harness connector.TERMINALS CONTINUITY REFERENCE
ECM IPDM E/R Continuity Connector Terminal Connector Terminal F7 24 E15 51 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES: GO TO 13.
NO: GO TO 12.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness or connectors F121, E7
- Harness for open or short between ECM and IPDM E/R
Repair open circuit or short to ground or short power in harness or connectors.
- CHECK 20A FUSE
- Disconnect 20A fuse (No. 62) from IPDM E/R.
- Check 20A fuse.
Is the inspection result normal?
YES: GO TO 17.
NO: Replace 20A fuse.
- CHECK GROUND CONNECTION-II
- Turn ignition switch OFF.
- Check ground connection E21. Refer to Ground Inspection in "CIRCUIT INSPECTION ".
Is the inspection result normal?
YES: GO TO 15.
NO: Repair or replace ground connection.
- CHECK ECM GROUND CIRCUIT FOR OPEN AND SHORT-II
- Disconnect ECM harness connector.
- Check the continuity between ECM harness connector and ground.TERMINALS CONTINUITY REFERENCE
ECM Ground Continuity Connector Terminal F7 12 Ground Existed 16 E16 107 108 111 112 - Also check harness for short to power.
Is the inspection result normal?
YES: GO TO 17.
NO: GO TO 16.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness or connectors F121, E7
- Harness for open or short between ECM and ground
Repair open circuit or short to power in harness or connectors.
- CHECK INTERMITTENT INCIDENT
Refer to "INTERMITTENT INCIDENT ".
Is the inspection result normal?
YES: Replace IPDM E/R.
NO: Repair open circuit or short to power in harness or connectors.