Recirculating-to-Discharge Air Temperature Table
WARNING: This page is about a different car, the 2006 Nissan Sentra. However, it is still accessible from the selected car via links, so may be relevant.
RECIRCULATING-TO-DISCHARGE AIR TEMPERATURE SPECIFICATION
| Inside air (Recirculating air) at blower assembly inlet | Discharge air temperature at center ventilator °C (°F) | |
|---|---|---|
| Relative humidity % | Air temperature °C (°F) | |
| 50 - 60 | 20 (68) | 6.6 - 8.3 (44 - 47) |
| 25 (77) | 10.4 - 12.4 (51 - 54) | |
| 30 (86) | 14.2 - 16.7 (58 - 62) | |
| 35 (95) | 18.2 - 21 (65 - 70) | |
| 40 (104) | 22.0 - 25.2 (72 - 77) | |
| 60 - 70 | 20 (68) | 8.3 - 9.8 (47 - 50) |
| 25 (77) | 12.4 - 14.4 (54 - 58) | |
| 30 (86) | 16.7 - 18.9 (62 - 66) | |
| 35 (95) | 21.0 - 23.6 (70 - 74) | |
| 40 (104) | 25.2 - 28.1 (77 - 83) | |