Mike's Workshop Manuals: Service manuals for every vehicle
Home >> Nissan-Datsun >> 2005 >> Sentra SE-R >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 2 (Engine Control System (QG18DE)) >> Trouble Diagnosis >> Consult-II Function (Engine) >> Inspection Procedure

Inspection Procedure

WARNING: This page is about a different variant/trim than selected.
  1. Turn ignition switch OFF.
  2. Connect CONSULT-II and CONSULT-II CONVERTER to data link connector, which is located under LH dash panel near the fuse box cover.
    Fig 1: Locating Data Link Connector
    G02449688Courtesy of NISSAN MOTOR CO., U.S.A.
  3. Turn ignition switch ON.
  4. Touch "START" (NISSAN BASED VHCL).
    Fig 2: CONSULT-II Display - "START" (NISSAN BASED VHCL)
    G02449689Courtesy of NISSAN MOTOR CO., U.S.A.
  5. Touch "ENGINE".

    If "ENGINE" is not indicated, go to "CONSULT-II DATA LINK CONNECTOR (DLC) CIRCUIT ".

    Fig 3: CONSULT-II Display - SELECT SYSTEM
    G02449690Courtesy of NISSAN MOTOR CO., U.S.A.
  6. Perform each diagnostic test mode according to each service procedure.

    For further information, see the CONSULT-II Operation Manual. 

    Fig 4: CONSULT-II Display - SELECT DIAG MODE
    G02449691Courtesy of NISSAN MOTOR CO., U.S.A.