Mike's Workshop Manuals: Service manuals for every vehicle
Home >> Nissan-Datsun >> 2005 >> Altima Base >> Repair and Diagnosis >> Engine Performance >> Engine Control System - Qr25DE >> DTC P0451: EVAP Control System Pressure Sensor >> DIAGNOSTIC TROUBLE CODES Confirmation Procedure >> With Consult-II

With Consult-II

  1. Turn ignition switch OFF and wait at least 10 seconds.
  2. Turn ignition switch ON and select "DATA MONITOR" mode with CONSULT-II.
  3. Start engine and wait at least 40 seconds.
    NOTE: Do not depress accelerator pedal even slightly.

    If 1st trip DTC is detected, go to "DIAGNOSTIC PROCEDURE "

    Fig 1: Display - DATA MONITOR Mode With CONSULT-II
    G02525136Courtesy of NISSAN MOTOR CO., U.S.A.