Power Supply and Ground Circuit Inspection
WARNING: This page is about a different car, the 2006 Nissan Xterra. However, it is still accessible from the selected car via links, so may be relevant.
- CHECK FUSES
Check for blown combination meter fuses.
FUSE REFERENCEUnit Power source Fuse No. Combination meter Battery 19 Ignition switch ON or START 14 Refer to "WIRING DIAGRAM - METER- ".
OK or NG
OK: GO TO 2.
NG: If fuse is blown, be sure to eliminate cause of malfunction before installing new fuse. Refer to "POWER SUPPLY ROUTING CIRCUIT ".
- CHECK POWER SUPPLY CIRCUIT
- Disconnect combination meter connector.
- Check voltage between combination meter harness connector terminals and ground.
IGNITION SWITCH POSITION REFERENCETerminals Ignition switch position (+) (-) OFF ACC ON Connector Terminal M24 3 Ground Battery voltage Battery voltage Battery voltage 16 0V 0V Battery voltage Courtesy of NISSAN MOTOR CO., U.S.A.
OK or NG
OK: GO TO 3.
NG: Check the harness for open between combination meter and fuse.
- CHECK GROUND CIRCUIT
- Turn ignition switch OFF.
- Check continuity between combination meter harness connector terminals and ground.
TERMINALS CONTINUITY REFERENCETerminals Continuity (+) (-) Connector Terminal M24 13 Ground Yes 23 OK or NG
OK: Inspection End.
NG: Repair harness or connector.