7) Check ECM Power Supply Circuit-II
- Reconnect ECM harness connector.
- Turn ignition switch ON.
- Check voltage between IPDM E/R terminal 17 and ground with CONSULT-II or tester.
- Voltage: Battery voltage
OK or NG
- OK: Go to , "IGNITION SIGNAL ".
- NG: GO TO 8.