Power Supply And Ground
Power is supplied at all times
- through 15A fuse [No. 22, located in the fuse block (J/B)] (2-door models) or
- through 20A fuse [No. 22, located in the fuse block (J/B)] (4-door models)
- to the stop lamp switch terminal 1.
When ignition switch is in the ON or START position, power is supplied
- through 10A fuse [No. 5, located in the fuse block (J/B)]
- to ASCD control unit terminal 5
- through 7.5A fuse [No. 12, located in the fuse block (J/B)]
- to park/neutral position switch terminal 1,
- through 10A fuse [No. 11, located in the fuse block (J/B)]
- to combination meter terminals 32 and 38.
When park/neutral position switch (A/T) is in the P or N position, ground is supplied
- to park/neutral position switch terminal 2
- through ASCD relay terminal 1
- to ASCD relay terminal 2
- through body grounds M14 and M68.
When ON.OFF switch is depressed (ON), ground is supplied
- to ASCD control unit terminal 11
- from ASCD steering switch terminal 13
- to ASCD steering switch terminal 14
- from ASCD control unit terminal 24.
Then ASCD control unit illuminates CRUISE indicator.
Ground is supplied.
- to combination meter terminal 36
- from ASCD control unit terminal 15.
Ground is supplied
- to ASCD control unit terminal 17
- through body grounds M14 and M68.