7. Check Condenser Power Supply Circuit-II For Open And Short
- Disconnect IPDM E/R harness connector E119.
- Check harness continuity between IPDM E/R terminal 13 and condenser terminal 1. Refer to Wiring Diagram.
- Continuity should exist.
- Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 12. CHECK INTERMITTENT INCIDENT .