Mike's Workshop Manuals: Service manuals for every vehicle
Home >> Nissan-Datsun >> 2003 >> Sentra SE-R, Standard >> Repair and Diagnosis >> External Pages >> Different car >> Section 535 (Power Door Lock System - Sedan) >> Power Door Lock System >> CONSULT-II Function (BCM) >> Consult-II Inspection Procedure

Consult-II Inspection Procedure

WARNING: This page is about a different car, the 2005 Infiniti G35. However, it is still accessible from the selected car via links, so may be relevant.
CAUTION: If CONSULT-II is used with no connection of CONSULT-II CONVERTER, malfunction might be detected in self-diagnosis depending on control unit which carry out CAN communication.
  1. Turn ignition switch "OFF".
  2. Connect "CONSULT-II" and "CONSULT-II CONVERTER" to the data link connector.
    Fig 1: Locating Data Link Connector
    G02354212Courtesy of NISSAN MOTOR CO., U.S.A.
  3. Turn ignition switch "ON".
  4. Touch "START". (NISSAN BASED VHCL)
    Fig 2: CONSULT-II Main Menu Display
    G02354213Courtesy of NISSAN MOTOR CO., U.S.A.
  5. Touch "BCM" on "SELECT SYSTEM" screen.

    If "BCM" is not indicated, go to CONSULT-II DATA LINK CONNECTOR (DLC) CIRCUIT .

    Fig 3: CONSULT-II Select System Display
    G02354214Courtesy of NISSAN MOTOR CO., U.S.A.
  6. Touch "DOOR LOCK" on "SELECT TEST ITEM" screen.
    Fig 4: CONSULT-II Select Test Item Display
    G02354215Courtesy of NISSAN MOTOR CO., U.S.A.
  7. Select diagnosis mode.

    "DATA MONITOR", "ACTIVE TEST" and "WORK SUPPORT" are available.

    Fig 5: CONSULT-II Select Diag Mode Display
    G02354216Courtesy of NISSAN MOTOR CO., U.S.A.