Check air passage continuity and operation delay time under the following conditions.

CONDITION VIAS SOL VALVE AND AIR PASSAGE CONTINUITY REFERENCE CHART

Condition Air passage continuity between A and B Air passage continuity between A and C
12V direct current supply between terminals 1 and 2 Yes No
No supply No Yes

Operation takes less than 1 second. 

Fig 1: Checking Air Passage Continuity