Diagnostic Procedure
- Turn ignition off. Disconnect ECM harness connector. See Figure or Figure . Check continuity between body ground and ECM harness connector terminal No. 66 (Black wire). See Figure . Continuity should exist. Also, check circuit for short to voltage. If problem is found, repair as necessary. If problem is not found, go to next step.
- Check fuel level sensor. See appropriate DIAGNOSTIC PROCEDURE under DTC P0460: FUEL LEVEL SENSOR SLOSH . If fuel level sensor is okay, go to next step. If fuel level sensor is not okay, replace fuel level sensor.
- No problem is indicated at this time. Problem may be intermittent. See INTERMITTENTS in TROUBLE SHOOTING - NO CODES article.