Check "L" Terminal Circuit
- CHECK "L" TERMINAL CONNECTION
Check to see if "L" terminal is clean and tight.
OK or NG
- OK: GO TO 2.
- NG: Repair "L" terminal connection. Confirm repair by performing complete Battery/Starting/Charging system test.
- CHECK "L" TERMINAL CIRCUIT
- Disconnect E35 connector from generator.
- Apply ground to connector E35 terminal L (Y/R) with the ignition switch in the ON position.
OK or NG
- OK: Replace the generator. Confirm repair by performing complete Battery/Starting/Charging system test.
- NG: Check the following.
- 10A fuse [No. 30, located in fuse block (J/B)]
- CHARGE lamp
- Harness for open or short between combination meter and fuse
- Harness for open or short between combination meter and generator