Temperature Control Cable & Heater Valve Control Rod
NOTE:
Before adjusting heater valve control rod, disconnect temperature control cable from blend-air door. After adjusting control rod, install temperature control cable and adjust it as necessary.
- Place temperature lever to maximum hot setting. Disconnect temperature control cable from blend-air door lever.
- Pull heater valve control rod in direction of arrow to obtain .08"(2.0 mm) clearance between ends of rod and link lever. See Fig 1 . Connect rod to door lever. Check operation of air mix door.
- Push temperature control cable and air mix door lever in direction of arrow. See Fig 2 . Install retaining clip.