  1. PERFORM SELF-DIAGNOSIS 

    Perform self-diagnosis of front camera unit.

    Is any DTC detected? 

    YES >>

    Perform diagnosis on the detected DTC and repair or replace the applicable item. Refer to DTC INDEX .

    NO >>

    GO TO  2.

  2. PREPARATION BEFORE CAMERA AIMING ADJUSTMENT 
    1. Perform pre-inspection for diagnosis.
    2. Adjust the tire pressure to the specified pressure value.
    3. Maintain no-load in vehicle.
    4. Check if coolant and engine oil are filled up to correct level and fuel tank is full.
    5. Shift the selector lever to "P" position and release the parking brake.
    6. Clean the windshield.
    7. Completely clear off the instrument panel.
    NOTE: If any fixed object is put on instrument panel, cover the upper of the instrument panel with black cloth to prevent an object from reflecting in the windshield.

    GO TO  3.

  3. PREPARATION OF J-52266-2 ALIGNMENT TARGET 

    Prepare the alignment target according to the following procedure and the figure.

    1. Attach the J-52266-2 alignment target to a movable board.
    NOTE:
    • Use the board that peripheral area of the target is monochrome such as a whiteboard.
    • Notice that the cross of the target is horizontal and vertical.
    G16265368Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.
    (1) White wall
    (2) String
    (3) Cone
    (4) Center between two targets

    Side of a target (Ts): 120 mm (4.72 in) 

    Height of a target lower end (Htl): 1, 180 mm (46.46 in) 

    Height of a target center (Ht): 1, 300 mm (51.18 in) 

    Height of a target upper end (Htu): 1, 420 mm (55.91 in) 

    Width between a right target center from a left target center (Dbt): 720 mm (28.35 in) 

    W1: 180 mm (7.09 in) 

    W2: 180 mm (7.09 in) 

    >>

    Proceed to